Communication Drivers

VisiWin is an open system not tying you to any specific panel. The same applies to communication with automation hardware such as control and drive systems.

In VisiWin, communication is uncoupled from the runtime system by means of a standardized OPC interface (Classic and/or UA) or proprietary drivers.

Of course, the drivers developed by INOSOFT are particularly well suited for the VisiWin runtime system and ensure optimal performance, stability and diagnostics.

You can combine VisiWin with various controllers and automation devices. Even at the same time...

VisiWin driver for communication with Simatic S7 compatible controllers via TCP/IP

Includes a browser for importing variables from Simatic Manager and TIA Portal

Supported control systems:

  • S7-200(TCP)/S7-300/S7-400
  • S7-1200/S7-1500 access to non-optimized data blocks/markers/I/O
  • NEW! S7-1200/S7-1500 (symbolic access to optimized data blocks)
  • WinAC/WinAC RTX
  • NEW! Simatic S7-PLCSIM Advanced
  • VIPA System 300S (Speed7)
  • SAIA various PCD of the xx7 series (Siemens Step7 compatible)
  • Various TCP/IP<=>MPI converters by Process-Informatik/Hilscher/IBHSoftec
  • S5 90U/95U/100U/115U/135U via adaptor TCP/IP (RFC1006) based on PG protocol AS511 (TTY)

VisiWin driver for communication with CoDeSys V2 compatible controllers via TCP/IP

(ARTI/L2Route/L4)

Supported control systems (a few examples):

  • Bosch Rexroth IndraMotion MLC L20, L40, L60, IndraLogic CML20/40
  • Lenze Logic and Motion
  • 3S CoDeSys runtime SP WIN V2.3/SP WIN RTE V2.3

VisiWin driver for communication with CoDeSys V3 compatible controllers via PLCHandler and gateway

Supported control systems (a few examples):

  • Bosch Rexroth IndraMotion MLC L25, L45, L65, IndraLogic, IndraLogic10
  • Lenze Logic and Motion V3
  • Schneider/Elau PacDrive3 LMC x00C/LMC x01C (SoMachine)
  • 3S CoDeSys runtime systems SP WIN V3/SP WIN RTE V3

VisiWin driver for communication with TwinCAT V2 and V3 via ADS

Supported control systems:

  • TwinCAT PLC runtime systems under Windows Standard or Windows CE
  • Intelligent controllers of the BXxxxx/CXxxxx series
  • TwinCat I/O

VisiWin driver for communication via TCP/IP

(Common Industrial Protocol/CIP)

Supported control systems:

  • Allen-Bradley CompactLogix and ControlLogix

VisiWin driver for communication with B&R control systems via PVI

Supported control systems:

  • B&R X20 System, System 2003, System2005, Power Panel

VisiWin driver for communication with various control systems via a serial interface (MODBUS ASCII or RTU) or TCP/IP (MODBUSoverIP)

Supported control systems:

  • Wago Ethernet controller of the 750 series with Modbus Over IP functionality, e. g. 750-880, 750-881, etc.
  • Phoenix Contact Modbus/TCP bus coupler
  • Schneider Modicon series (Quantum *, Premium *), Logic Controller Modicon M*, Modicon TSX Micro
  • SAIA PCD controllers
  • And many more

Connection to various controllers manufactured by Jetter AG, e. g. of the JetControl series.

The following communication interfaces are supported:

  • JETSTX
  • JETWay
  • PCPPLC
  • JETIP

Connection to various controllers manufactured by Bachmann, e. g. processor modules of the MX200 series.

The following communication protocols are supported:

  • TCP
  • QSOAP
  • SSL
  • UDP

OPC-DA AND OPC-UA

A client for OPC DA and OPC UA connectivity to the latest standard is arbitrarily included in the system and does not need to be additionally licensed.

 

YOU COULD NOT FIND YOUR SYSTEM?

Contact us. VisiWin provides many more drivers, also for prior automation systems. And the list is growing steadily...

Even linking to a proprietary system is possible. To develop an individual driver a driver toolkit is available that allows you to sinply develop your own driver in C# based on Microsoft.NET. Of course we can do that for you, too.